1. How high the garden lamp is generally high

The height of general garden Lights is between 2.5 meters and 5 meters.Modern garden lamps are mostly customized courtyard Lights, so the height can be customized according to customer requirements. Generally, 3 meters-4 meters are used in the community. The garden Lights on the sides of the road on both sides of the urban road or on both sides of the pedestrian road areGenerally at 4 meters to 5 meters; followed by some of the garden Lights produced by molds (such as the height of the courtyard Lights of die-cast aluminum), it is generally fixed at about 2.8 meters-3.5 meters.

2. Basic size of the garden Lights

1. The height of the garden light

The height of general garden Lights is between 2.5 meters and 5 meters.

2. The size of the courtyard lamp flange

The size of the courtyard lamp flange is generally 280x280, and the unit is millimeter.

3. Court -light burial size

The size of the courtyard lamp is 500cm.

4. The bottom size of the courtyard light

The basic size of the garden light base is 400cm.

5. Specifications of the garden Lights

The specifications of the garden Lights are 115mm and other diameters, 219mm, etc.

6. The courtyard light cone rod ratio ratio ratio ratio

The cone ratio ratio of the garden Lights is generally 11 .

Third, the practice of courtyard Lights

1. Sample sample

Positioning in strict accordance with the labeling in the construction drawings, according to the benchmark point and reference elevation delivered by the resident supervision engineer, use the level instrument to put samples, and submit it to the resident supervision engineer for inspection.

2. Guding pit excavation

Strictly excavate the foundation pit in strictly in accordance with the design requirements and geometric size. After excavation, clean up the base and consolidate the base.

3. Basic pour

(1) Strictly follow the material specifications specified in the design drawings and the method of systematic system regulations, carry out the system and installation of basic reinforced bars, and check the resident supervision engineers.

(2) Basic embedded parts should be treated with hot -dip galvanized treatment.

(3) The concrete pouring must be stirred strictly according to the material ratio, and poured according to the horizontal level. The thickness of the vibration must not exceed 45cm to prevent the two layers from getting off.

(4) Pour the concrete two times, and the first pouring to about 20cm above the anchor plate. After the concrete is frozen, remove the residue, accurately correct the embedded bolts, then pour the concrete of the remaining part, and ensure the foundation of the foundationThe level of installation level of the flange plate is not more than 1%.

Disclaimer: The above method stems from the index of the program system or the sharing of netizens. It is for your reference only and does not represent the research perspective of this website. It proves that it is effective. Please pay attention to the authenticity and authority of the source of the content of the content.Apply to delete & gt; & gt;Correction & gt; & gt;